JS EN 50294:2012 Measurement method of total input power of ballast-lamp circuits EN 50294:1998 + A1:2001 + A2:2003

This Jordanian Standard gives the measurement method of the total input power for ballast-lamp circuits when operating with their associated fluorescent lamp(s). This standard applies to electrical ballast-lamp circuits comprised solely of the ballast and of the lamp(s). (Published Document (JS))

JS IEC 62031:2012 LED modules for general lighting ـــ Safety specifications

This International Standard specifies general and safety requirements for light-emitting diode (LED) modules: LED modules without integral control gear for operation under constant voltage, constant current or constant power; self-ballasted LED modules for use on d.c. supplies up to 250 V or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz. (Published Document (JS))

JS EN 61347-1:2012 Lamp controlgear Part 1: General and safety requirements

This part of standard specifies general and safety requirements for lamp controlgear for use on d.c. supplies up to 250 V and/or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz. (Published Document (JS))

JS IEC 61347-2-8:2012 Lamp controlgear Part 2-8: Particular requirements for ballasts for fluorescent lamps

This part of IEC 61347 specifies safety requirements for ballasts, excluding resistance types, for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with fluorescent lamps with or without pre-heated cathodes operated with or without a starter or starting device and having rated wattages, dimensions and characteristics as specified in IEC 60081 and 60901. (Published Document (JS))

JS 61347-2-7:2009 Lamp controlgear Part 2-7: Particular requirements for d.c. supplied electronic ballasts for emergency lighting

This standard specifies particular safety requirements for d.c supplied electronic ballasts for maintained and non-maintained emergency lighting purpose (Published Document (JS))

JS 61347-2-2:2009 Lamp controlgear Part 2-2-: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps

This standard specifies particular safety requirement for electronic step-down convertors for use on d.c supplies up to 250V or a.c supplies up to 1000 V at 50 hz or 60 hz (Published Document (JS))

JS 61347-2-3:2009 Lamp controlgear Part 2-3: Particular requirements for a.c. supplied electronic ballasts for fluorescent lamps

this standard specifies particular safety requirements for electronic ballasts for use on a.c supplies up to 1 000 V at 50 hz with operating frequem\ncies deviating from the supply frequenvy (Published Document (JS))

JS 61347-2-13:2009 Lamp controlgear Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules

This standard specifies particular safety requirements for electronic controlgear for use on d.c supplies up to 250 V and a.c supplies up to 1 000 V at 50 Hz or 60 Hz and at an output frequency which can deviate from the supply frequency associated with LED modules. (Published Document (JS))

JS 61347-2-10:2009 Lamp controlgear Part 2-10: Particular requirements electronic invertors and convertors for high-frequency operation of cold start tubular discharge lamps (neon tubes)

This standard specifies particular requirements for electronic invertors and convetors for high-frequency operation of tubular cold-cathode discharge lamps used in signs and luminous discharge tube installations and operating wuth an output voltage (Published Document (JS))

JS 61347-1:2009 Lamp controlgear Part 1: General and safety requirements

This part of standard specifies general and safety requirements for lamp controlgear for use on d.c. supplies up to 250 V and/or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz. (Withdrawn Document)

JS 61347-2-8:2008 Lamps controlgear Part 2- 8 : Particular requirements for ballasts for fluorescent lamps

This part of IEC 61347 specifies safety requirements for ballasts, excluding resistance types, for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz, associated with fluorescent lamps with or without pre-heated cathodes operated with or without a starter or starting device and having rated wattages, dimensions and characteristics as specified in IEC 60081 and 60901. (Withdrawn Document)

JS 61347-2-12:2008 Lamp controlgear Part 2-12 : Particular requirements for d. c or a.c. supplied electronic ballasts for discharge lamps (excluding fluorescent lamps)

This standard specifies particular general and safety requirement for d.c or a.c supplied electronic ballasts the supply comprises a.c voltage up to 1000 V at 50 Hz/60 Hz the type of ballast is an convertor that may contain igniting and stablising elements for operation of a discharge lamp at d.c (Published Document (JS))

JS 61347-2-4:2008 Lamps controlgear Part 2-4 : Particular requirements for d. c supplied electronic ballasts for general lighting

This standard specifies particular safety requirements for d.c. supplied electronic ballasts intended for operation from transient and surge-free power sources, operated directly from batteries without chaging equipment as used in leisure equipment, (Published Document (JS))

JS 62094-1:2008 Indicator light units for household and similar fixed-electrical installations Part 1 : General requirements

This standard applies to stand-alone indicator light units intended to give a visible signal. they are designed for a.c. only with a rated voltage not exceeding 440 V and a rated power 10 W, for household and similar fixed-electrical installations, either indoors or outdoors. (Published Document (JS))

JS 61347-2-9:2008 Lamp controlgear Part 2-9 : Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps)

This standard specifies particular safety requirements for ballasts for ballasts for discharge lamps such as high-pressure mercury vapour, low-pressure sodium vapour, high-pressure sodium vapour and metal halide lamps. and covers inductive-type ballasts for use on a.c. supplies up to 1 000 V at 50Hz or 60 Hz, associated with discharge lamps (Published Document (JS))

JS 61347-2-1:2008 Lamp controlgear Part 2-1 : Particular requirements for starting devices (other than glow starters)

This standard specifies particular safety requirements for starting devices (starters other than glow starters and ignitors) for fluorescent and other discharge lamps for use on a.c. supplies up to 1 000 V at 50 Hz or 60 Hz which produce starting pulses not greater than 100 kV and which are used in comination with lamps and ballasts (Published Document (JS))

JS 60155:2008 Glow-starters for flourescent lamps

this standard is specifies general, safety and performance requirements for glow-starters flourescent lamps. (Withdrawn Document)

JS 10018:2007 Decorative oil lamps - Safety requirements and test methods