Fuses and other overcurrent protection devices

# ICS Title
Search Results
JS EN 50550:2012 Power frequency overvoltage protective device for household and similar applications (POP)

This Jordanian Standard applies to power frequency overvoltage protection devices (hereafter referred to as “POP”) for household and similar uses, with a rated frequency of 50 Hz, a rated voltage 230 V a.c. (between phase and neutral), intended to be used in combination with a main protective device being either a CB in compliance with EN 60898-1 (Published Document (JS))

JS EN 61643-21:2012 Low voltage surge protective devices part 21: surge protective devices connected to telecommunications and signaling networks – performance requirements and testing methods

This International Standard is applicable to devices for surge protection of telecommunications and signalling networks against indirect and direct effects of lightning or other transient overvoltages. The purpose of these SPDs is to protect modern electronic equipment connected to telecommunications and signalling networks with nominal system voltages up to 1 000 V (r.m.s.) a.c. and 1 500 V d.c. (Published Document (JS))

JS EN 60898-1:2012 Electrical accessories ـــ Circuit breakers for overcurrent protection for household and similar installations Part 1: Circuit-breakers for a.c. operation

This part of IEC 60898 applies to a.c. air-break circuit-breakers for operation at 50 Hz or 60 Hz, having a rated voltage not exceeding 440 V (between phases), a rated current not exceeding 125 A and a rated short-circuit capacity not exceeding 25 000 A. (Published Document (JS))

JS EN 62020:2012 Electrical accessories - Residual current monitors for household and similar uses (RCMs)

This International Standard applies to residual current monitors having rated voltages not exceeding 440 V a.c. and rated currents not exceeding 125 A for household and similar purposes.These devices are intended to monitor the residual current of the installation and to give a warning if the residual current between a live part and an exposed conductive part or earth exceeds a predetermined level (Published Document (JS))

JS IEC 60934:2010 Circuit-breakers for equipment (CBE)

This Standard is applicable to mechanical switching devices designed as 'circuit-breakers for equipment' (CBE) intended to provide protection to circuits within electrical equipment. (Published Document (JS))

JS IEC 60269-1:2010 Low-voltage fuses Part 1: General requirements

This standard applicable to fuses incorporating enclosed current-limiting fuse-links with rated breaking capacities of not less than 6 KA. (Published Document (JS))

JS IEC 60127-6:2010 Miniature fuses Part 6: Fuse-holders for miniature fuse-links

This part of js127 is applicable to fuse-holders for miniature cartridge fuse-links according to IEC 127-2 and sub-miniature fuse-links according to js 127-3 for the protection of electric appliances, electronic equipment and component pa rts thereof, normally intended for use indoors. (Published Document (JS))

JS IEC 60269-4:2010 Low-voltage fuses Part 4: Supplementary requirements for fuse-links for the protection of semiconductor devices

This standard supplementary requirement apply to fuse-link for application in equipment containing semiconductor device for circuits of nominal voltage up to 1000 V a.c to 1500 v d.c and also in so far as they are applicable for circuits of higher nominal (Published Document (JS))

JS 60127-3:2009 Miniature fuses Part 3: Sub-miniature fuse-links

Requirements applicable to sub-miniature fuse-links adapted to printed circuits used for protection of appliances and equipment used indoors. Appliances used under special conditions are excluded. (Published Document (JS))

JS 60127-2:2009 Miniature fuses Part 2: Cartridge fuse-links

This part of JS 60127 relates to special requirements applicable to cartridge fuse-links for miniature fuses with dimensions measuring 5 mm ? 20 mm and 6,3 mm ? 32 mm for the protection of electric appliances, electronic equipment and component parts thereof, normally intended for use indoors. (Published Document (JS))

JS 60898-2:2009 Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations Part 2: Circuit-breakers for a.c and d.c. operation

This standard gives additional requirements for single- and two-pole circuit-breakers which, in addition to the above characteristics, are suitable for operation with direct current, and have a rated d.c. voltage not exceeding 220 V for single-pole and 440 V for two-pole circuit-breakers, a rated current not exceeding 125 A and a rated d.c. short-circuit capacity not exceeding 10 000 A. (Published Document (JS))

JS 60127-1:2009 Miniature fuses Part 1: Definitions for miniature fuses and general requirements for miniature fuse-links

This part of standard covers the general requirements and tests applicable to all types of miniature fuse-links (e.g. cartridge fuse-links, sub-miniature fuse-links and universal modular fuse-links) for the protection of electric appliances, electronic equipment and component parts thereof normally intended to be used indoors (Published Document (JS))

JS 60898-1:2009 Electrical accessories - Circuit breakers for overcurrent protecion for household and similar installations Part 1: Circuit-breakers for a.c. operation

This part of standard applies to a.c. air-break circuit-breakers for operation at 50 Hz or 60 Hz, having a rated voltage not exceeding 440 V (between phases), a rated current not exceeding 125 A and a rated short-circuit capacity not xceeding 25 000 A. (Withdrawn Document)

JS EN 61009-1:2009 Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses ( RCBO's ) Part 1: General rules

This standard applies to residual current operated circuit-breakers with integral overcurrent protection functionally dependent on, line voltage for household and similar uses (hereafter referred to as RCBOs), for rated voltage not exceeding 440 V a. c. (Published Document (JS))

JS 60691:2008 Thermal-Links - Requirements and application guide

This International Standard is applicable to thermal-links intended for incorporation in electrical appliances, electronic equipment and component parts thereof, in order to protect them against excessive temperatures under abnormal conditions. (Published Document (JS))

JS 60931-3:2008 Shunt power capacitors of the non-self-healing type for a.c systems having a rated voltage up to and including 1 kV Part 3: Internal fuses

This standard applies to internal fuses which are designed to isolate faulty capacitor elements or a capacitor unit, in order to allow operation of the remaining parts of that capacitor unit and the bank in which the capacitor unit is connected (Published Document (JS))

JS 60269-4:2007 Low-voltage fuses Part 4: Supplementary requirements for fuse-links for the protection of semiconductor devices

This standard specifies the supplementray requirements apply fo fuse-links for application in equipment containing semiconductor devices for circuits of rated voltage up 1000 V a . c or circuits of nominal voltage up 10 1500 V d . c . (Withdrawn Document)

JS 60269-1:2007 Low-voltage fuses Part 1: General requirements

This standard specific the generalrequirements for fuses incorporating enclosed current-limiting fuse-links. (Withdrawn Document)

JS 60127-6:2007 Miniature fuses - Part 6: Fuse-holders for miniature fuse-links

This standard gives applicable fuse-household for miniature cartridge fuse-links accordung to protection the electronic equipment and component. (Withdrawn Document)

JS 60269-4-1:2007 Low-voltage fuses Part 4-1: Supplementary requirements for fuse-links for the protection of semiconductor devices Sections I to III: Examples of types of standardized fuse-links

This standard specifies the supplementary requirements apply to fuse-links having bolted connections whos dimensions comply with the requirements . (Withdrawn Document)

JS 61009-2-1:2007 Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) Part 2-1: Applicability of the general rules to RCBOs functionally independent of line voltage

This standard applies to residual current operated circuit-breakers with integral overcurrent protection independent of line voltage for household and similar uses. (Published Document (JS))

JS 60127-4:2007 Miniature fuses - Part 4: Universal modular fuse-links (UMF) - Through-hole and surface mount types

This part of standard relates to universal modular fuse-links ( UMF) for printed circuits and other substrate systems. (Published Document (JS))

JS 61008-2-1:2007 Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB,s) Part 2-1: Applicability of the general rules to RCCB,s functionally independent of line voltage

This International Standard applies to RCCB?s functional ly indepent of line voltage, for household and similar uses, not incorporatting overcurrent protection. (Published Document (JS))

JS 61173:2007 Over voltage protection for photovoltaic (PV) power generating systems - Guide

This standard gives guidance on the protection of overvoltage issues for both stand-alone and grid-connected photovoltaic power generating systems. It is intended to identify sources of overvoltage hazards to define the types of protection such as grounding, shielding, stroke interception and protective devices. (Published Document (JS))

JS 61008-1:2007 Residual current opertaed circuit - breakers without integral overcurrent protection for household and similar uses ( RCCBs) Part 1:General rules

This International Standard applies to residual current operated circuit-breakers functionally independent of, or functionally dependent on, line voltage, for household and similar uses, not incorporating overcurrent protection (hereafter referred to as RCCBs), for rated voltages not exceeding 440 V a.c. and rated currents not exceeding 125 A. (Published Document (JS))

JS 1043:1996 Circuit breakers - Circuit-breakers for over current protection for houshold and similar installations

Applies to a.c.air-break circuit-breakers for operation at 50 Hz or 60 Hz having arated voltage not exceeding 440 V (between phases), a rated currentno exceeding 125 A and a rated short circuit capacity not exceeding25000 A (Withdrawn Document)

JS 934:1993 Electrical appliances - Residualcurrent operated circuit-breakers without integral overcurrent -Protection for household and similar uses - Part 1: General rules

Includes generalrules related to residual current operated circuit breakers withoutintegral overcurrent for protection in household and similar uses (Withdrawn Document)