Power capacitors

Search Results
JS IEC 61921:2012 Power capacitors - Low-voltage power factor correction banks

This International Standard is applicable to low-voltage a.c. capacitor banks intended to be used for power factor correction purposes, equipped with a built-in switchgear and controlgear apparatus capable of connecting to or disconnecting from the mains part(s) of the bank with the aim to correct its power factor. (Published Document (JS))

JS IEC 60143-2:2010 Series capacitors for power systems Part 2 : Protective equipment for series capacitor banks

This part of IEC 143 covers protective equipment for series capacitor banks, with a size larger than 10 Mvar per phase. Protective equipment is defined as the main circuit apparatus and ancillary equipment, which are part of a series capacitor installation, but which are external to the capacitor part itself. given in IEC 143. (Published Document (JS))

JS 60831-1:2009 Shunt power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 kV Part 1: General - Performance, testing and rating - Safety requirements - Guide for installation and operation

This part of standard is applicable to both capacitor units and capacitor banks intended to be used, particularly, for power-factor correction of a.c. power systems having a rated voltage up to and including 1000 V and frequencies 15 Hz to 60 Hz. (Published Document (JS))

JS EN 61071:2009 Capacitors for power electronics

This standard applies to capacitors for power electronics applications the operation frequency of the systems in which these capacitors are used is usually up to 15khz while the pulse frequencies may be up to 5 to 10 times the operating frequency. (Published Document (JS))

JS 60931-1:2008 Shunt Power capacitors of the non-self-healing type for a.c. systems having a rated voltage up to and including 1 kV Part 1: General - Performance, testing and rating - Safety requirements - Guide for installation and operation

This part of standard is applicable to both capacitor units and capacitor banks intended to be used, particularly, for power-factor correction of a.c. power systems having a rated voltage up to and including 1 000 V and frequencies 15 Hz to 60 Hz. (Published Document (JS))

JS 60831-2:2008 Shunt Power capacitors of the self-healing type for a.c. systems having a rated voltage up to and including 1 kV Part 2: Ageing test, self-healing test and destruction test

This part of standard applies to capacitors according to JS 60831-1 and gives the requirements for the ageing test self-aling test and destruction test for these capacitors. (Published Document (JS))

JS 60931-3:2008 Shunt power capacitors of the non-self-healing type for a.c systems having a rated voltage up to and including 1 kV Part 3: Internal fuses

This standard applies to internal fuses which are designed to isolate faulty capacitor elements or a capacitor unit, in order to allow operation of the remaining parts of that capacitor unit and the bank in which the capacitor unit is connected (Published Document (JS))

JS 60931-2:2008 Shunt Power capacitors of the non-self-healing type for a.c. systems having a rated voltage up to and including 1 kV Part 2: Ageing test and destruction test

This standard applies to capacitors according to IEC 931-1 and gives the requirements for the ageing test and destruction test for these capacitors. (Published Document (JS))

JS 60143-2:2007 Series capacitors for power systems Part 2 : Protective equipment for series capacitor banks

This standard specifies the series capacitors for power systems and the protective equipments for series capacitors banks. (Withdrawn Document)

JS 60252-1:2007 AC motor capacitors Part 1: General - Performance, testing and rating - Safety requriements - Guide for installation and protection

This standard applies to motor capacitors intended for connection to windings of asynchronous motors supplied from a single-phase system having a frequency up to and including 100 Hz, and to capacitors to be connected to three-phase. (Published Document (JS))

JS 60252-2:2007 AC motor capacitors Part 2: Motor start capacitors

This standard applies to motor start capacitors intended for connection to windings of asynchronous motors suppled from a single-phase system having the frequency of the mains. (Published Document (JS))

JS 60110-1:2007 Power capacitors for induction heating installations Part 1: General

This standard applicable to indoor capacitor and banks used particulary factor correction with controlled a.c. voltage systems up to 50 Hz, 3,6k V. (Published Document (JS))