JS EN 50363-5:2013 Insulating, sheathing and covering materials for low voltage energy cables Part 5: Halogen-free, cross-linked insulating compounds
This part of EN 50363 specifies the requirements for the physical properties of the harmonised halogen-free, cross-linked insulating compounds given in Table 1. The relevant test methods are given in EN 60811 series, EN 50267-2 (series), EN 60684-2 and EN 50396.
(Published Document (JS))
|
JS EN 50363-3:2013 Insulating, sheathing and covering materials for low voltage energy cables Part 3: PVC insulating compounds
This part of EN 50363 specifies the requirements for the physical properties of the PVC insulating compounds given in Table 1. The relevant test methods are given in EN 60811 series and EN 50395.
(Published Document (JS))
|
JS EN 50290-2-24:2013 Communication cables Part 2-24: Common design rules and construction ـــ PE sheathing
This Part 2-24 of EN 50290 gives specific requirements for PE sheathing compounds used in communication cables.
(Published Document (JS))
|
JS EN 50290-2-29:2013 Communication cables Part 2-29: Common design rules and construction ـــ Cross-linked PE insulation compounds
This Part 2-29 of EN 50290 includes requirements for cross-linked PE insulation compounds used in communication cables.
(Published Document (JS))
|
JS EN 50363-8:2013 Insulating, sheathing and covering materials for low voltage energy cables Part 8: Halogen-free, thermoplastic sheathing compounds
This part of EN 50363 specifies the requirements for the physical properties of the harmonised halogen-free thermoplastic sheathing compound given in Table 1. The relevant test methods for verification of compliance are given in EN 60811 (series), EN 50267-2 series, EN 60684-2, EN 50396 and HD 21.14.
(Published Document (JS))
|
JS EN 50290-2-27:2013 Communication cables Part 2-27: Common design rules and construction ـــ Halogen free flame retardant thermoplastic sheathing compounds (AC:2010)
This Part 2-27 of EN 50290 gives specific requirements for halogen free flame retardant thermoplastic sheathing compounds used in communication cables.
(Published Document (JS))
|
JS EN 50290-2-23:2013 Communication cables Part 2-23: Common design rules and construction ـــ PE insulation
This part 2-23 of EN 50290 gives specific requirements for PE insulated compounds used for communication cables.
(Published Document (JS))
|
JS EN 50363-2-1:2013 Insulating, sheathing and covering materials for low voltage energy cables Part 2-1: Cross-linked elastomeric sheathing compounds
This part of EN 50363 specifies the requirements for the physical properties of the cross-linked elastomeric sheathing compounds given in Table 1. The relevant test methods are given in EN 60811 series and EN 50396.
(Published Document (JS))
|
JS EN 50290-2-30:2013 Communication cables Part 2-30: Common design rules and construction ـــ Poly (tetrafluoroethylene - hexafluoropropylene) (FEP) insulation and sheathing
This Part 2-30 of EN 50290 gives specific requirements for poly(tetrafluoroethylene-hexafluoropropylene) (FEP) insulation and sheathing used in communication cables.
(Published Document (JS))
|
JS EN 50290-2-28:2013 Communication cables Part 2-28: Common design rules and construction ـــ Filling compounds for filled cables
This Part 2-28 of EN 50290 gives specific requirements for filling compounds for filled cables used in communication cables.
(Published Document (JS))
|
JS EN 50290-2-25:2013 Communication cables Part 2-25: Common design rules and construction ـــ Polypropylene insulation compounds
This Part 2-25 of EN 50290 gives specific requirements for polypropylene insulation compounds used in communication cables.
(Published Document (JS))
|
JS EN 50363-6:2013 Insulating, sheathing and covering materials for low voltage energy cables Part 6: Halogen-free, cross-linked sheathing compounds
This part of EN 50363 specifies the requirements for the physical properties of the harmonised halogen-free cross-linked sheathing compounds given in Table 1. The relevant test methods for verification of compliance are given in EN 60811 (series), EN 50267-2 (series), EN 60684-2 and EN 50396.
(Published Document (JS))
|
JS EN 50290-2-26:2013 Communication cables Part 2-26: Common design rules and construction ـــ Halogen free flame retardant insulation compounds (A1:2007)
This Part 2-26 of EN 50290 gives specific requirements for halogen free flame retardant insulation compounds used in communication cables.
(Published Document (JS))
|
JS EN 50497:2010 Recommended test method for assessment of the risk of plasticizer exudation from PVC insulated and sheathed cables
The test method described in this Standard shows, by the use of accelerated testing, discrete exudation of plasticizer from PVC insulated and sheathed cables. It is for use in circumstances where the manufacturer determines that there may be a specific risk that
cannot be assessed only by use of the compatibility test
(Published Document (JS))
|
JS IEC 60811-2-1:2010 Insulating and sheating materials of electric and optical cables - Common test methods Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests
This standard specifies the test methods to be used for testing polymeric insulating and sheathing materials of electric and optical cables for power distribution and telecommunications, including cables used on ships and in offshore applications.
(Published Document (JS))
|
JS 50363-0:2008 Insulating, sheathing and covering materials for low-voltage energy cables Part 0: General introduction
This part of EN 50363 contains, in its various parts, the requirements for insulating, sheathing and covering
materials that are used for harmonized low voltage energy cabl.
(Withdrawn Document)
|
JS 50363-2-1:2008 Insulating, sheathing and covering materials for low-voltage energy cables Part 2-1 : Cross-linked elastomeric sheathing compounds
This standard specifies requirement for the physical properties of the cross-linked elastomeric sheathing compounds
(Withdrawn Document)
|
JS 50363-2-2:2008 Insulating, sheathing and covering materials for low-voltage energy cables Part 2-2 : Cross-linked elastomeric covering compounds
This standard specifies the requirement for the physical properties of the cross-linked elastomeric covering compound
(Published Document (JS))
|
JS 50363-1:2008 Insulating sheathing and covering materials for low-voltage energy cables Part 1 : Cross-linked elastomeric insulating compounds
This part of EN 50363 specifies the requirements for the cross-linked elastomeric insulating
compounds given in Table 1. The relevant test methods are given in EN 60811 series and EN 50396
(Published Document (JS))
|
JS 50363-6:2008 Insulating, sheathing and covering materials for low-voltage energy cables Part 6 : Halogen-free, cross-linked sheathing compounds
This standard specifies the requirements for the physical properties of the harmonised halogen-free cross-linked sheathing compounds
(Withdrawn Document)
|
JS 50363-10-2:2008 Insulating, sheathing and covering materials for low-voltage energy cables Part 10-2 : Miscellaneous sheathing compounds - Thermoplastic polyurethane
This standard specifies the test requirements for the physical properties of the harmoised thermoplastic polyurethane sheating compound
(Published Document (JS))
|
JS 50363-4-2:2008 Insulating, sheathing and covering materials for low-voltage energy cables Part 4-2 : PVC covering compounds
0
(Published Document (JS))
|
JS 50363-7:2008 Insulating sheathing and covering materials for low-voltage energy cables Part 7 : Halogen-free, thermoplastic insulating compounds
This standard specifies the requirements for the physical properties of the harmonised halogen-free cross-linked sheathing compounds
(Published Document (JS))
|
JS 50363-3:2008 Insulating, sheating and covering materials for low-voltage energy cables Part 3 : PVC insulating compounds
This Standard is specifies the requirements for the the physical properties of the PVC insulating compounds
(Withdrawn Document)
|
JS 50363-10-1:2008 Insulating, sheathing and covering materials for low-voltage energy cables Part 10-1 : Miscellaneous sheathing compounds - Cross-linked polyvinyl chloride (XLPVC)
This standard specifies the test requirements for the physical properties of the harmonised cross-linked PVC
(Published Document (JS))
|
JS 50363-9-1:2008 Insulating, sheathing and covering materials for low-voltage energy cables Part 9-1 : Miscellaneous insulating compounds - Cross-linked polyvinyl chloride ( XLPVC)
This standard is speccifies the test requirements for the physical properties of the harmonised cross-linked PVC insulating compound and relevant test methods
(Published Document (JS))
|
JS 50363-5:2008 Insulating, sheathing and covering materials for low-voltage energy cables Part 5 : Halogen-free, cross-linked insulating compounds
This standard specifies the requirements for the physical properties of the harmonised halogen-free cross-linked insulating compounds
(Withdrawn Document)
|
JS 50363-8:2008 Insulating, sheathing and covering materials for low-voltage energy cables Part 8 : Halogen-free, thermoplastic sheathing compounds
This Standard specifies the requirements for the physical properties of the harmonised halogen-free thermoplastic sheathing compound given in table 1 and the relevant test methods for verification of compliance
(Withdrawn Document)
|
JS 50363-4-1:2008 Insulating, sheathing and covering materials for low-voltage energy cables Part 4-1 : PVC sheathing compounds
This standard specifies the requirement for the physical properties of the PVC sheathing compounds given in table 1.
(Published Document (JS))
|
JS 60811-4-2:2007 Insulating and sheathing materials of electric and optical cables - Common test methods Part 4-2: Methods specific to polyethylene and polypropylene compounds - Tensile strength and elongation at break after conditioning at elevated temperature - Warpping test after conditioning at elevated temperature - Warpping test after thermal ageing in air-Measurement of mass increase - Long-term stability test - Test method for copper-catalyzed oxidative degradation
This part of standard specifies the test methods for testing polymeric insulating and sheathing materials of electric and optical fiber cable for power distribution and communications including cables used on ships and on offshore applictions.
(Published Document (JS))
|
JS 60811-3-1:2007 Insulating and sheathing materials of electric and optical cables - Common test methods Part 3-1: Methods specific to PVC compounds - Pressure test at high temperature - Tests for resistance to cracking
This standard specifies the test methods to be used for testing polymeric insulating and sheathing
materials of electric cables for power distribution and telecommunications including cables used on ships. and in offshore applications.
This Section 1 of Part 3 gives the methods for pressure test at high temperature and for tests for resistance to cracking, which apply to PVC compounds.
(Published Document (JS))
|
JS 60811-4-1:2007 Insulating and sheathing materials of electric and optical cables - Common test methods Part 4-2: Methods specific to polyethylene and polypropylene compounds - Resistance to environmental stress cracking - measurement of the melt flow index - Carbon black and/ or mineral filler content measrement in polyethylene by direct combustion - Measurement of carbon black content by thermogravimetric analysis (TGA) - Assessment of carbon black dispersion in polyethylene using a microscope
This part of standard specifies the test methods to be used for testing polym eric insulating and sheathing materials of electric and optical fibre cables for power distribution and telecom-munications, including cables used on ships and in offshore applications. These test methods
apply specifically to PE and PP compounds, including cellular compounds and foam skin.
(Published Document (JS))
|
JS EN 60811-3-2:2007 Insulating and sheathing materials of electric and optical cables - Common test methods Part 3-2: Methods specific to PVC compounds - Loss of mass test _ Thermal stability test
This standard specific the test methods for PVC compounds used for polymeric insulating and sheathing materials for power distribution and telecommunication.
(Published Document (JS))
|
JS 416-2:2005 Insulating materials-Specifications for pressure-sensitive adhesive tapes for electrical purposes Part2: Methods of test
This standard spechfhes methods of test for pressure - sensitive adhesive tapes for electrical purposes.
(Published Document (JS))
|
JS 416-1:2001 Insulating material - Specification for pressure - Sensitive adhesive tapes for electrical purposes Part1 : General requirements
This standard specifies for sensitive adhesive tapes for electrical purposes
(Published Document (JS))
|