This Jordanian Standard applies to newly manufactured watt-hour meters, measuring active electrical energy, intended for residential, commercial and light industrial use, for use on 50 Hz electrical networks. It specifies general requirements and type tests methods. It applies to electromechanical or static watt-hour meters for indoor and outdoor application, consisting of a measuring element (Published Document (JS))
This standard applies to the protection of persons and animals against electric sock it is intended to give fundamental principles and requirements which are common to electrical installations systems and equipment or necessary for their co-ordination. (Published Document (JS))
This part of JS 44 covers the requirements and tests, in addition to those in Chapter I of IJS 185, that are necessary for inductive current transformers for use with electrical protective schemes in which the prime requirement for the current transformers is the maintenance of a defined pe rformance up to several times the rated current. (Published Document (JS))
Concerns of voltage bands for electrical installations of buildings (Published Document (JS))
Lays down method of protection for persons, fixedequipment and fixed material adjacent to electrical equipment againstharmful effect of heat that was generated by electrical equipment orthermal radiation (Published Document (JS))
specify of electrical installtions of buildings and protectionagainst undervoltage (Published Document (JS))
Applies for the purpose of testing quality control and aceptanceof electrical installtions of building (Published Document (JS))
deals with non automatic local and remote isolation and switching measures which prevent or remove dangers associated with electrical installations or electrically powered equipments and machines. (Published Document (JS))
deals mainly with devices ensuring protection against over load current and short circuit with the co-ordination between conductors and protective devices with the characteristics of short circuit protective devices with the coordination of over load and short circuit protection and with the limitation of over current by characteristics of supply . (Published Document (JS))
containsrequirement which shall be observed in addition deals mainly with thecondition of evacuation in an emergency and the nature of processedor stored materials (Published Document (JS))
Concerns testing, acceptance and qualitymonitoring for electrical installtions in building for the purpose ofprotection against fire (Withdrawn Document)
Applies to electrical installation in building (Withdrawn Document)
Concerns insulation and switching of electrical installations inbuilding for the purpose of safety (Withdrawn Document)
Applies for the purposes of testing, acceptance andquality control for electrical installations in buildings in order tobe safe against thermal effects (Withdrawn Document)
Includes general specifications ofelectrical installations in building (Withdrawn Document)
Applies to electrical installations in building fed by 50 Hz a.c andrated voltage up to 1000 V (Withdrawn Document)
Applies for the purpose of testing,quality control and acceptance of electrical installations inbuilding and specifies the conditions of its design, construction andoperation (Withdrawn Document)