Fibres and cables

Search Results
JS 60332-2-2:2007 Tests on electric and optical fibre cables under fire conditions Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame

This part of IEC 60332 specifies the procedure for testing the resistance to vertical flame propagation for a single small vertical electrical insulated conductor or cable, or optical cable, under fire conditions. The apparatus is given in IEC 60332-2-1. (Published Document (JS))

JS 50266-2-2:2007 Common test methods for cables under fire conditions - Test for vertical flam spread of vertically - Mounted bunched wires or cables - Part 2-2 : Procedures-category A

This test isintended for type approval testing. the requirements for the selection of cables for testing are given in annex A. (Published Document (JS))

JS 50266-2-3:2007 Common test methods for cables under fire conditions - Test for vertical flame spread of vertically-mounted bunched wires or cables - Part 2-3: Procedures - Category B

This part of standard covers category B and relates to cables installed on the test ladder to achieve a nominal total volume of non-metallic of 3.5 litres per metre of test sample. (Published Document (JS))

JS 50266-2-4:2007 Common test methods for cables under fire conditions - Test for vertical flame spread of vertically-mounted bunched wires or cables - Part 2-4 : Procedures-category C

This standard specifies method of test for the assessment of vertical flame spread of vertically-mounted bunched wires or cables, electrical or optical under defined conditions (Published Document (JS))

JS 60332-1-2:2007 Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame

This part of IEC 60332 specifies the procedure for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions. The apparatus is given in IEC 60332-1-1. (Published Document (JS))

JS 50266-1:2007 Common test methods for cables under fire conditions - Test for vertical flame spread of vertically - mounted bunched wires or cables - Part 1: Apparatus

Specifies methods of test for the assessment of vertical flam spread of vertically-mounted bunched wires or cables, electrical or optical, under defined conditions. (Published Document (JS))

JS 50266-2-1:2007 Common test methods for cables under fire conditions -Test for vertical flame spread of vertically-mounted bunched wires or cables - Part 2-1 : Procedures-category A F/R

This part 2-1 covers category A F/R and relates only to power cables of conductor cross-swctional area grater than 35 mm installed on the test ladder in a spaced configuration on the front and rear to achieve a nominal total volume of non-metallic material of 7 liters per metre of test sample. (Published Document (JS))

JS 60332-1-3:2007 Tests on electric and optical fibre cables under fire conditions Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles

This part of standard specifies a test procedure for assessment of falling flaming droplets/ particles when a single vertical electrical insulated conductor or cable, or optical fibre cable, is subjected to defined fire conditions. (Published Document (JS))