Fire-resistance of building materials and elements

Search Results
JS 1397-5:2003 fire-resistance tests - Elements of building construction - Part4 : Specific requirements for loadbearing horizontal separating elements

Specicfies the procedures to be followed for determining the fire resistance non-loadbearing horizontal separating elements, when exposed to heating from underside (Published Document (JS))

JS 1397-8:2003 Fire-resistance test - Elements of building construction - Part 8: Specific requirements for non-loadbearing vertical separating elements

Specicfies the procedures to be followed for determining the fire resistance non-loadbearing vertical separating elements, when exposed to heating on one face. (Published Document (JS))

JS 1397-9:2003 Fire-resistance tests - Elements of building construction - Part 9: Specific requirements for non-loadbearing ceiling elements

Specicfies the procedures to be followed for determining the fire resistance non-loadbearing ceiling elements which possess fire resistance independent of any building element above them, when exposed to heating from below the ceiling (Published Document (JS))

JS 1397-6:2003 Fire-resistance tests - Elements of building construction - Part6: Specific requirements for beams

Specicfies the procedures to be followed for determining the fire resistance of beams, when tested on their own (Published Document (JS))

JS 1397-7:2003 Fire-resistance tests - Elements of building construction - Part 7 : Specific requirements for columns

Specicfies the procedures to be followed for determining the fire resistance non-loadbearing of columns when tested on their own (Published Document (JS))

JS 1397-3:2003 Fire-resistance tests - Elements of building construction - Part 3:Commentary on test method and test data application

Provide guidance on the use of fire resistance test method and the application of the data obtained (Published Document (JS))

JS 1397-4:2003 Fire-resistance tests - Elements of building construction Part 4: Specific requirements for loadbearing vertical separating elements

This part specifies the procedures to be followed for determining the fire resistance of loadbearing vertical separating elemnts when exosed on one face (Published Document (JS))

JS 1477:2002 Fire test - Building materials - Non-combustibility test

Specifies a method of test for the determination of the combustibalities performance of a building material under specified conditions (Published Document (JS))

JS 1398-1:2000 Fire tests - Evaluation of performance of smoke control door assemblies Part 1: Ambient temperature test

specifies the evaluation of performance of smokeand ambient temperature test (Published Document (JS))

JS 1396:2000 Fire-resistance tests - Door and shutter assemblies

Specifies methods of testing and assessing thefire resistance of elements of construction intended for closingopenings in walls (Published Document (JS))

JS 1397-1:2000 Fire-resistance tests - Elements of building construction - Part 1: General requirements

specifiesfor fire resistance tests and elements of building construction (Published Document (JS))